Water Sump and Tank Capacity Calculator

Work out how many litres a sump or tank holds, or what size to build for your household, in feet-inches or metres.

Sump details

Calculate
Units
Shape

The depth of water, not counting the air gap at the top.

135 litres is a planning default. Use measured demand and local supply requirements.

Usually 9 to 12 inches.

Wall and base thicknesses are excavation allowances, not structural specifications.

Wall

Results

Water capacity
13,592.16 litres
About 2.3 tanker loads of 6,000 litres
Volume
13.59
Cubic metres
Volume
480.00
Cubic feet, or 3,590.67 US gallons
Days of supply
20.14
For 5 people at 135 litres a day
Excavation
20.32 m³
717.75 ft³ with 6 in RCC walls and a 6 in base

Cross-section

Cross-section of the sump showing water depth and air gapAir gap 0' 9" (228.60 mm)Water 6' 0" · 13,592.16 LGround level

Estimate only. Confirm quantities with your engineer or contractor. Read more

How sump capacity is worked out

Capacity is the volume of water the sump holds, measured on the inside and only up to the water line:

Capacity formulas
ShapeVolumeIn litres
Rectangularlength × width × water depthft³ × 28.317, or m³ × 1,000
Roundπ × (diameter ÷ 2)² × water depthft³ × 28.317, or m³ × 1,000

For family sizing, the water needed is people × litres per person per day × days of storage. The suggested size uses estimating proportions of 1.4 : 1 : 1.1 for length, width and water depth.

Excavation adds the wall thickness on every side, plus the air gap and a 6 inch (150 mm) base slab below the water depth.

Worked example: a 10 × 8 ft sump with 6 ft of water

  1. Volume: 10 × 8 × 6 = 480 ft³.
  2. Litres: 480 × 28.317 = 13,592.16 litres, or 13.59 m³.
  3. Tanker loads: 13,592.16 ÷ 6,000 = about 2.3 loads.
  4. A family of 5 at 135 litres each uses 675 litres a day, so it lasts about 20.14 days.

Planning a sump

Daily water use

The editable 135 litres per person per day is a planning starting point. Demand varies with community size, occupancy, fixtures and extra uses. IS 1172:1993 distinguishes supply conditions; 135 litres is not a universal requirement for every city home. Use the local authority requirement and measured consumption where available.

Sump and overhead tank together

Size the sump for 1.5 to 2 times the daily demand, or more where supply is unreliable, and the overhead tank for half a day to one day. The sump covers supply cuts; a smaller overhead tank keeps the load on the roof down.

Walls and base

The excavation estimate assumes 6 inch RCC or 9 inch brick walls and a 6 inch base. These fixed allowances do not establish structural adequacy. Wall thickness, reinforcement, watertightness, vehicle loads and uplift when the tank is empty need a site-specific design.

Frequently asked questions

How do I work out sump capacity in litres from feet and inches?
Turn each measurement into decimal feet (feet + inches ÷ 12), multiply length × width × water depth to get cubic feet, then multiply by 28.317, because 1 ft³ holds 28.317 litres. A 10 × 8 ft sump with 6 ft of water holds 480 ft³, which is about 13,592 litres.
How much water does one person use per day in India?
This calculator starts at an editable 135 litres per person per day. IS 1172:1993 distinguishes community and supply conditions rather than setting one universal city-home demand. Use measured household consumption and the local authority requirement, including any garden or other extra use.
What size sump does a family of 4 or 5 need?
At 135 litres per person, a family of 5 uses about 675 litres a day. Keeping 3 days in reserve needs about 2,000 litres, and many builders allow 5,000 to 8,000 litres to cover longer supply cuts and tanker deliveries. A 7 × 5 ft sump with 5 ft of water holds about 5,000 litres.
How big should the sump be compared with the overhead tank?
A common rule is a sump of 1.5 to 2 times the daily demand and an overhead tank of half a day to one day of demand. The sump covers supply cuts, and the smaller overhead tank keeps the load on the roof down.
Why leave an air gap (freeboard) at the top?
Keep 225 to 300 mm (9 to 12 inches) between the highest water level and the roof slab. The gap gives the float valve room to work, lets the tank breathe, and leaves space for the overflow so water cannot flow back into the supply line.
Should the sump be RCC or brick?
The calculator offers 6 inch RCC and 9 inch brick thicknesses only to estimate excavation. It does not select a safe construction type. Have an engineer check soil, groundwater uplift, loading, reinforcement and watertightness before choosing walls and a base.
Esc